Number of Standard
|
|
|
IEC
|
EN or HD
|
EQUIPMENT
|
|
|
|
CABLE TRUNKING SYSTEMS AND CABLE DUCTING SYSTEMS FOR ELECTRICAL INSTALLATIONS
|
|
|
EN 50085-1
|
Part 1: General requirements
|
| |
|
|
|
CONDUIT SYSTEMS FOR CABLE MANAGEMENT
|
|
IEC 61386-1
|
EN 50086-1
|
Part 1: General requirements
|
|
IEC 61386-21
|
EN 50086-2-1
|
Part 2-1: Particular requirements for rigid conduit systems
|
|
IEC 61386-22
|
EN 50086-2-2
|
Part 2-2: Particular requirements for pliable conduit systems
|
|
IEC 61386-23
|
EN 50086-2-3
|
Part 2-3: Particular requirements for flexible conduit systems
|
|
IEC 61386-24
|
EN 50086-2-4
|
Part 2-4: Particular requirement for conduit systems buried underground
|
| |
|
|
|
ENVIRONMENTAL TESTING - Part 2: Tests
|
|
IEC 60068-2-6
|
EN 60068-2-6
|
Test Fc: Vibration (sinusoidal)
|
|
IEC 60068-2-11
|
EN 60068-2-11
|
Test Ka Salt mist
|
|
IEC 60068-2-20
|
|
Test T: Soldering
|
|
IEC 60068-2-27
|
EN 60068-2-27
|
Test Ea and guidance: Shock
|
|
IEC 60068-2-30
|
EN 60068-2-30
|
Test Db and guidance: Damp heat, cyclic (12 + 12 hour cycle)
|
| |
|
|
|
ELECTRICAL RELAYS
|
|
IEC 60255-5
|
|
Part 5: Insulation tests for electrical relays
|
|
IEC 60255-8
|
EN 60255-8
|
Part 8: Thermal electrical relays
|
|
IEC 60255-12
|
|
Part 12: Directional relays and power relays with two input energizing quantities
|
|
IEC 60255-13
|
|
Part 13: Biased percentage differential relays
|
| |
|
|
|
LOW VOLTAGE FUSES
|
|
IEC 60269-1
|
EN 60269-1
|
Part 1: General requirements
|
|
IEC 60269-2
|
EN 60269-2
|
Part 2: Supplementary requirements for fuses for use by authorized persons
|
|
IEC 60269-3
|
EN 60269-3
|
Part 3: Supplementary requirements for fuses for use by unskilled persons for fuses for use by unskilled persons
|
|
IEC 60269-4
|
EN 60269-4
|
Part 4: Supplementary requirements for fuse-links for the protection of semiconductor devices
|
| |
|
|
|
PLUGS, SOCKET-OUTLETS COUPLERS FOR INDUSTRIAL PURPOSES
|
|
IEC 60309-1
|
EN 60309-1
|
Part 1: General requirements
|
|
IEC 60309-2
|
EN 60309-2
|
Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories
|
| |
|
|
|
LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES
|
|
IEC 60439-1
|
EN 60439-1
|
Part 1: Type-tested and partially type-tested assemblies
|
|
IEC 60439-2
|
EN 60439-2
|
Part 2: Particular requirements for busbar trunking systems (busways)
|
|
IEC 60439-3
|
EN 60439-3
|
Part 3: Distribution Boards
|
|
IEC 60439-4
|
EN 60439-4
|
Part 4: Particular requirements for assemblies for construction sites
|
|
IEC 60439-5
|
EN 60439-5
|
Part 5: Cable distribution cabinets (CDCs) for power distribution networks
|
|
IEC 61439-1
|
EN 61439-1
|
Part 1: General rules
|
|
IEC 61439-2
|
EN 61439-2
|
Part 2: Power switchgear and controlgear assemblies
|
|
IEC 61439-5
|
EN 61439-5
|
Part 5: Assemblies for power distribution in public networks
|
| |
|
IEC 60529
|
EN 60529
|
DEGREES OF PROTECTION PROVIDED BY ENCLOSURES
|
| |
|
|
|
SWITCHES FOR HOUSEHOLD AND SIMILAR FIXED ELECTRICAL INSTALLATIONS
|
|
IEC 60669-1
|
EN 60669-1
|
Part 1: General requirements
|
| |
|
IEC 60755
|
|
RESIDUAL CURRENT OPERATED PROTECTIVE DEVICES
|
| |
|
IEC 60898
|
EN 60898
|
CIRCUIT BREAKERS FOR OVER CURRENT PROTECTION FOR HOUSEHOLD + SIMILAR
|
| |
|
|
|
LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR
|
|
IEC 60947-1
|
EN 60947-1
|
Part 1: General rules
|
|
IEC 60947-2
|
EN 60947-2
|
Part 2: Circuit breakers
|
|
IEC 60947-3
|
EN 60947-3
|
Part 3: Switches, disconnectors, switch-disconnectors and fuse combination units
|
|
|
|
Part 4: Contactors and motor starters
|
|
IEC 60947-4-1
|
EN 60947-4-1
|
Sect. 1: Electrotechnical contactors and motor starters
|
|
IEC 60947-4-2
|
EN 60947-4-2
|
Sect. 2: AC semicontactor motor controllers and starters
|
|
IEC 60947-4-3
|
EN 60947-4-3
|
Sect. 3: AC semicontactor controllers and contactors for non-motor loads
|
|
|
|
Part 5: Control circuit devices and switching elements
|
|
IEC 60947-5-1
|
EN 60947-5-1
|
Sect. 1: Electromechanical control circuit devices
|
|
IEC 60947-5-2
|
EN 60947-5-2
|
Sect. 2: Proximity switches
|
|
IEC 60947-5-5
|
EN 60947-5-5
|
Sect. 5: Electrical emergency stop devices with mechanical latching function
|
|
IEC 60947-5-6
|
EN 60947-5-6
|
Sect. 6: DC interface for proximity sensors and switching amplifiers (NAMUR)
|
|
IEC 60947-5-8
|
|
Sect. 8: Enabling control devices
|
|
IEC 60947-5-9
|
|
Sect. 9: Flow rate switches
|
|
|
|
Part 6: Multiple function equipment
|
|
IEC 60947-6-1
|
EN 60947-6-1
|
Sect. 1: Automatic transfer switching equipment
|
|
IEC 60947-6-2
|
EN 60947-6-2
|
Sect. 2: Control and protective switching devices (CPS)
|
|
|
|
Part 7: Ancillary Equipment
|
|
IEC 60947-7-1
|
EN 60947-7-1
|
Sect. 1: Terminal blocks for copper conductors
|
|
IEC 60947-7-2
|
EN 60947-7-2
|
Sect. 2: Protective conductor terminal blocks for copper conductors
|
|
IEC 60947-7-3
|
EN 60947-7-3
|
Sect. 3: Ancillary equipment - Safety requirements for fuse terminal blocks
|
| |
|
|
|
RESIDUAL CURRENT CIRCUIT-BREAKERS FOR HOUSEHOLD AND SIMILAR USE (RCCBs)
|
|
IEC 61008-1
|
EN 61008-1
|
Part 1: General rules
|
|
IEC 61008-2-1
|
EN 61008-2-1
|
Part 2-1: Applicability of the general rules to RCCB's functionally independent of line voltage
|
|
IEC 61008-2-2
|
|
Part 2-2: Applicability of the general rules to RCCB's functionally dependent on line voltage
|
| |
|
|
|
RESIDUAL CURRENT CIRCUIT-BREAKERS HOUSEHOLD AND SIMILAR (RCCOBs)
|
|
IEC 61009-1
|
EN 61009-1
|
Part 1: General rules
|
|
IEC 61009-2-1
|
EN 61009-2-1
|
Part 2-1: Applicability of the general rules to RCBO's functionally independent of line voltage
|
|
IEC 61009-2-2
|
|
Part 2-2: Applicability of the general rules to RCBO's functionally dependent on line voltage
|
| |
|
IEC 61095
|
EN 61095
|
ELECTROMECHANICAL CONTACTORS FOR HOUSEHOLD AND SIMILAR PURPOSES
|
| |
|
|
|
PROGRAMMABLE CONTROLLERS
|
|
IEC 61131-1
|
EN 61131-1
|
Part 1: General information
|
|
IEC 61131-2
|
EN 61131-2
|
Part 2: Equipment requirements
|
| |
|
|
|
SAFETY OF TRANSFORMERS POWER SUPPLY UNITS AND SIMILAR
|
|
IEC 61558-1
|
EN 61558-1
|
Part 1: General requirements and tests
|
|
IEC 61558-2-1
|
EN 61558-2-1
|
Part 2-1: Particular requirements for separating transformers for general use
|
|
IEC 61558-2-4
|
EN 61558-2-4
|
Part 2-4: Particular requirements for isolating transformers for general use
|
|
IEC 61558-2-6
|
EN 61558-2-6
|
Part 2-6: Particular requirements for safety isolating transformers for general use
|
| |
|
|
|
SPECIFIED TIME RELAYS FOR INDUSTRIAL USE
|
|
IEC 61812-1
|
EN 61812-1
|
Part 1: Requirements and tests
|
| |
|
|
|
ELECTRIC VEHICLE CONDUCTIVE CHARGING System
|
|
IEC 61851-1
|
EN 61851-1
|
Part 1: General requirements
|
|
IEC 61851-22
|
EN 61851-22
|
Part 22: AC electric vehicle charging station
|
| |
|
|
|
ELECTROMAGNETIC COMPATIBILITY (EMC)
|
|
|
|
Part 3: Limits
|
|
IEC 61000-3-2
|
EN 61000-3-2
|
Part 3-2: Limits for harmonic current emission (equipment input current <= 16 A per phase)
|
|
IEC 61000-3-3
|
EN 61000-3-3
|
Part 3-3: Limitation of voltage changes, voltage fluctuations flicker in public low voltage supply systems, for equipment with rated current <= 16 A per phase and not subjected to conditional connection
|
|
|
|
Part 4: Testing and measurement techniques
|
|
IEC 61000-4-2
|
EN 61000-4-2
|
Part 4-2: Electrostatic discharge immunity test
|
|
IEC 61000-4-3
|
EN 61000-4-3
|
Part 4-3: Radiated radio frequency, electromagnetic field immunity
|
|
IEC 61000-4-4
|
EN 61000-4-4
|
Part 4-4: Electrical fast transient/burst
|
|
IEC 61000-4-5
|
EN 61000-4-5
|
Part 4-5: Surge immunity test
|
|
IEC 61000-4-6
|
EN 61000-4-6
|
Part 4-6: Immunity to conducted disturbances, induced by radio-frequency fields
|
|
IEC 61000-4-8
|
EN 61000-4-8
|
Part 4-8: Power frequency magnetic field immunity test
|
|
IEC 61000-4-9
|
EN 61000-4-9
|
Part 4-9: Pulse magnetic field immunity test
|
|
IEC 61000-4-10
|
EN 61000-4-10
|
Part 4-10: Damped oscillator magnetic field immunity test
|
|
IEC 61000-4-11
|
EN 61000-4-11
|
Part 4-11: Voltage dips, short interruptions and voltage variation immunity tests
|
|
|
|
Part 6: Generic standards
|
|
IEC 61000-6-3
|
EN 61000-6-3
|
Part 6-3: Generic standards -Emission standard for residential commercial and light industrial environments
|
|
IEC 61000-6-4
|
EN 61000-6-4
|
Part 6-4: Generic standards -Emission standard for industrial environments
|
| |
|
|
|
ELECTRICAL ACCESSORIES- CIRCUITBREAKER AND SIMILAR EQUIPMENT FOR HOUSEHOLD USE
|
|
IEC 62019
|
EN 62019
|
Auxiliar contact units
|
| |
|
|
|
Empty enclosures for low-voltage switchgear and controlgear assemblies
|
|
IEC 62208
|
EN 62208
|
General requirements
|
| |
| |
|
Remark:
|
Grey-shodowed Standards:
|
These standards are not used for granting LOVAG Mark Licences
|